Carbon steel fastener for fixing the membrane faced insulation panel to heavy section steel
Estimated lead times
1 Day
Estimated lead times
1 Day
Specially designed carbon steel fastener for fixing membrane faced sandwich panels to heavy steel.
Features
- Unique head design for easy 'one step fix' installation. The foam remains in place after penetration so there is no need to fill the hole
- Moulded head with 5 precise cutting notches for efficient coring of the Kingspan TopDek panel
- Rotationally symmetrical for balanced loading and directional stability
- 11mm Bi-hex and TX30 drive options
- For fastening membrane faced composite panels to steel 4-12mm thick
Years / Environment
|
|||||||
---|---|---|---|---|---|---|---|
Interior | Semi-interior | Rural | Urban | Industrial / Coastal | Marine | Swimming pools & Chemical plants | |
Corrosivity Category | C1 | - | C2 | C3 | C4 | C5 | - |
Carbon steel case hardened | 25 | 20 | 12 | 0 | 0 | 0 | 0 |
NR,II,K (Tensile - Pull-out) | 4mm Steel: 5.44 kN |
6mm Steel: 12.75 kN | |
8mm Steel: 13.92 kN |
Installation tool | Variable speed electric screw gun |
Installation drive | Fixfast Bi-hex MF11285 |
Installation speed | 1500 RPM |
Correct installation | Fasteners should be driven within three degrees of perpendicular to the surface of the fastened material. Use a depth-setting nosepiece to avoid over-driving, and do not over-tighten. Variants with bonded washers should not have the rubber compressed to less than two-thirds of its uncompressed height. Care should be taken when engaging and disengaging from the fastener head to avoid damage to the protective coating. |
Handling | Fasteners may have sharp edges, and the use of power tools can be dangerous. Use personal protective equipment. Store fasteners in dry conditions. Inspect each fastener before use and do not use damaged fasteners. |
Specially designed carbon steel fastener for fixing membrane faced sandwich panels to heavy steel.
Features
- Unique head design for easy 'one step fix' installation. The foam remains in place after penetration so there is no need to fill the hole
- Moulded head with 5 precise cutting notches for efficient coring of the Kingspan TopDek panel
- Rotationally symmetrical for balanced loading and directional stability
- 11mm Bi-hex and TX30 drive options
- For fastening membrane faced composite panels to steel 4-12mm thick
Years / Environment
|
|||||||
---|---|---|---|---|---|---|---|
Interior | Semi-interior | Rural | Urban | Industrial / Coastal | Marine | Swimming pools & Chemical plants | |
Corrosivity Category | C1 | - | C2 | C3 | C4 | C5 | - |
Carbon steel case hardened | 25 | 20 | 12 | 0 | 0 | 0 | 0 |
NR,II,K (Tensile - Pull-out) | 4mm Steel: 5.44 kN |
6mm Steel: 12.75 kN | |
8mm Steel: 13.92 kN |
Installation tool | Variable speed electric screw gun |
Installation drive | Fixfast Bi-hex MF11285 |
Installation speed | 1500 RPM |
Correct installation | Fasteners should be driven within three degrees of perpendicular to the surface of the fastened material. Use a depth-setting nosepiece to avoid over-driving, and do not over-tighten. Variants with bonded washers should not have the rubber compressed to less than two-thirds of its uncompressed height. Care should be taken when engaging and disengaging from the fastener head to avoid damage to the protective coating. |
Handling | Fasteners may have sharp edges, and the use of power tools can be dangerous. Use personal protective equipment. Store fasteners in dry conditions. Inspect each fastener before use and do not use damaged fasteners. |