High corrosion-resistant stainless steel self-drilling fastener for fixing to timber, aluminium and steel decks in corrosive environments such as swimming pools, tunnels, industrial plants and marine areas.
Designed for use with SureFast tube washers for fixing flat roofing insulation and membrane to metal or timber decks.
- Manufactured from 1.4529 grade stainless steel with high (6-7%) molybdenum content for high corrosion resistance
- Buttress thread ensures excellent pull-out performance and resistance to unwinding
- Torx 25 recess head style
- ETA Approval and CE Marked
- For mechanically fixing single-ply and flat roofing systems to steel and timber decks in combination with appropriate SureFast components
Years / Environment
|
|||||||
---|---|---|---|---|---|---|---|
Interior | Semi-interior | Rural | Urban | Industrial / Coastal | Marine | Swimming pools & Chemical plants | |
Corrosivity Category | C1 | - | C2 | C3 | C4 | C5 | - |
HCR Austenitic Stainless Grade 1.4529 | 40 | 40 | 40 | 40 | 35 | 25 | 20 |
Years / Environment
|
|||||||
---|---|---|---|---|---|---|---|
Interior | Semi-interior | Rural | Urban | Industrial / Coastal | Marine | Swimming pools & Chemical plants | |
Corrosivity Category | C1 | - | C2 | C3 | C4 | C5 | - |
HCR Austenitic Stainless Grade 1.4529 | 40 | 40 | 40 | 40 | 35 | 25 | 20 |
Years / Environment
|
|||||||
---|---|---|---|---|---|---|---|
Interior | Semi-interior | Rural | Urban | Industrial / Coastal | Marine | Swimming pools & Chemical plants | |
Corrosivity Category | C1 | - | C2 | C3 | C4 | C5 | - |
HCR Austenitic Stainless Grade 1.4529 | 40 | 40 | 40 | 40 | 35 | 25 | 20 |
NR,II,K (Tensile - Pull-out) | 0.9mm Aluminium Sheet Rm 241 Mpa: 1.07 kN |
1.5mm Aluminium Sheet Rm 241 Mpa: 2.06 kN | |
18mm Plywood: 2.46 kN | |
Timber 38mm embedment: 2.75 kN |
NR,II,K (Tensile - Pull-out) | 0.9mm Aluminium Sheet Rm 241 Mpa: 1.07 kN |
1.5mm Aluminium Sheet Rm 241 Mpa: 2.06 kN | |
18mm Plywood: 2.46 kN | |
Timber 38mm embedment: 2.75 kN |
NR,II,K (Tensile - Pull-out) | 0.9mm Aluminium Sheet Rm 241 Mpa: 1.07 kN |
1.5mm Aluminium Sheet Rm 241 Mpa: 2.06 kN | |
18mm Plywood: 2.46 kN | |
Timber 38mm embedment: 2.75 kN |
Installation tool | Variable speed electric screw gun |
Installation drive | TX25 |
Installation speed | 1500 RPM |
Correct installation | Fasteners should be driven within three degrees of perpendicular to the surface of the fastened material. Use a depth-setting nosepiece to avoid over-driving, and do not over-tighten. Variants with bonded washers should not have the rubber compressed to less than two-thirds of its uncompressed height. Care should be taken when engaging and disengaging from the fastener head to avoid damage to the protective coating. |
Handling | Fasteners may have sharp edges, and the use of power tools can be dangerous. Use personal protective equipment. Store fasteners in dry conditions. Inspect each fastener before use and do not use damaged fasteners. |
High corrosion-resistant stainless steel self-drilling fastener for fixing to timber, aluminium and steel decks in corrosive environments such as swimming pools, tunnels, industrial plants and marine areas.
Designed for use with SureFast tube washers for fixing flat roofing insulation and membrane to metal or timber decks.
- Manufactured from 1.4529 grade stainless steel with high (6-7%) molybdenum content for high corrosion resistance
- Buttress thread ensures excellent pull-out performance and resistance to unwinding
- Torx 25 recess head style
- ETA Approval and CE Marked
- For mechanically fixing single-ply and flat roofing systems to steel and timber decks in combination with appropriate SureFast components
Years / Environment
|
|||||||
---|---|---|---|---|---|---|---|
Interior | Semi-interior | Rural | Urban | Industrial / Coastal | Marine | Swimming pools & Chemical plants | |
Corrosivity Category | C1 | - | C2 | C3 | C4 | C5 | - |
HCR Austenitic Stainless Grade 1.4529 | 40 | 40 | 40 | 40 | 35 | 25 | 20 |
Years / Environment
|
|||||||
---|---|---|---|---|---|---|---|
Interior | Semi-interior | Rural | Urban | Industrial / Coastal | Marine | Swimming pools & Chemical plants | |
Corrosivity Category | C1 | - | C2 | C3 | C4 | C5 | - |
HCR Austenitic Stainless Grade 1.4529 | 40 | 40 | 40 | 40 | 35 | 25 | 20 |
Years / Environment
|
|||||||
---|---|---|---|---|---|---|---|
Interior | Semi-interior | Rural | Urban | Industrial / Coastal | Marine | Swimming pools & Chemical plants | |
Corrosivity Category | C1 | - | C2 | C3 | C4 | C5 | - |
HCR Austenitic Stainless Grade 1.4529 | 40 | 40 | 40 | 40 | 35 | 25 | 20 |
NR,II,K (Tensile - Pull-out) | 0.9mm Aluminium Sheet Rm 241 Mpa: 1.07 kN |
1.5mm Aluminium Sheet Rm 241 Mpa: 2.06 kN | |
18mm Plywood: 2.46 kN | |
Timber 38mm embedment: 2.75 kN |
NR,II,K (Tensile - Pull-out) | 0.9mm Aluminium Sheet Rm 241 Mpa: 1.07 kN |
1.5mm Aluminium Sheet Rm 241 Mpa: 2.06 kN | |
18mm Plywood: 2.46 kN | |
Timber 38mm embedment: 2.75 kN |
NR,II,K (Tensile - Pull-out) | 0.9mm Aluminium Sheet Rm 241 Mpa: 1.07 kN |
1.5mm Aluminium Sheet Rm 241 Mpa: 2.06 kN | |
18mm Plywood: 2.46 kN | |
Timber 38mm embedment: 2.75 kN |
Installation tool | Variable speed electric screw gun |
Installation drive | TX25 |
Installation speed | 1500 RPM |
Correct installation | Fasteners should be driven within three degrees of perpendicular to the surface of the fastened material. Use a depth-setting nosepiece to avoid over-driving, and do not over-tighten. Variants with bonded washers should not have the rubber compressed to less than two-thirds of its uncompressed height. Care should be taken when engaging and disengaging from the fastener head to avoid damage to the protective coating. |
Handling | Fasteners may have sharp edges, and the use of power tools can be dangerous. Use personal protective equipment. Store fasteners in dry conditions. Inspect each fastener before use and do not use damaged fasteners. |
Client Technical Services
Fixfast's technical team provides a range of calculations and technical services to contractors and architects looking to purchase or specify our products. You can find out more about these services here, or register a request below.
Upload a plan for your tapered insulation scheme, and we’ll calculate the optimum fastener requirements for each insulation board thickness.
Windload calculations typically for flat roofing projects using our SureFast flat roofing fastener systems, in accordance with BS EN 1991-1-4:2005 +A1:2010.